Frequency Inverter CV100 Series

Frequency Inverter CV100 Series

Frequency Inverter CV100 Series

200W - 400W - 750W - 1500W - 2200W

More details...

156,00 € tax incl.

130,00 €tax excl.

Frequency Inverter CV100 Series

Power : 200W - 400W - 750W - 1500W - 2200W

Carrier Frequency up to 15kHz

Output Frequency : 0 - 300Hz

Auto torque boost and auto slip compensation function

Built-in PID control

Wall mounting

 

1 RS485 Modbus port

1 10v reference voltage output

2 analog input -10~+10V

5 digital multi-function input, Optocoupler isolation

2 analog output 0~10V or 0/4~20mA

1 optocoupled output, open collector 30V - 50mA

1 relay output, 250VAC - 2A, 30VDC - 1A

1 power supply output  +24V - 200 mA

 

External dimension <=1500W : 

W : 85mm

H : 142mm

D : 122mm

Weight : 0.8 kg

 

External dimension 2200W : 

W : 101mm

H : 152mm

D : 127mm

Weight : 1 kg

 

 Characteristics :

ItemDescription
Input Rated voltage and frequency 4T : triphase 380V~440V – 50Hz/60Hz // 2S : singlephase 200V~240V
Allowable voltage range 4T : 320V~460V – 2S : 180V~260V – Voltage unbalancedness <3 % - Frequency +-5 %
Output Rated Voltage 0~Rated input voltage
Frequency 0Hz~300Hz (0Hz~1000Hz custom)
Overload capacity Type G : 150% 1 mn – 180% 10 s
Main controls characteristics Controle method V/F control
Starting torque Auto torque rising
Frequency accuracy Digital setting : max. frequency x +- 0.01% – Analog setting : max. frequency x +-0.2 %
Frequency resolution Digital setting : 0.01Hz – Analog setting : max. frequency x 0.05 %
Torque boost Manual torque boost : 0% ~ 30.0 %
V/F patterns 4 patterns : 1 V/F curve mode set by user and 3 kinds of torque- derating modes (2.0 power - 1.7 power - 1.2 power)
Acc/Dec curves Linear/deceleration. Four kinds of acceleration/deceleration time
Auto current limit Limit current durinf operation automatically to prevent
Customized function Operation command Keypad setting – Terminal setting – Communication setting
Frequency command Digital setting – analog voltage setting – analog current setting
Auxiliary frequency setting Implement flexible auxiliary frequency trim and frequency synthesis
Analog output 2 channel analog output (0/4~20mA or 0/2~10V)
Protection function Overcurrnet protection - overvoltage protection – undervoltage protection – overheat protection – overload protection – missing phase protection (selectable) and so on
Environnement Indoor - installed in the environnement free from direct sunlight – dust – corrosive gas – combustible gas – oil mist – steam and drip
Altitude Derated above 1000m – the rated output current shall be decreased by 10% for every rise of 1000m
Ambient temperature -10°C~40°C - derated at 40°C~50°C
Humidity 5%~95%RH – non-condensing
Vibration Less than 5.9m/s2 (0.6g)
Storage temperature -40°C~70°C
Structure Protection class IP20
Cooling method air cooling with fan control
Installation method Wall mounting
efficiency ≥ 93 %

 

 

Connections :

CategoryMarquage Description
Shield PE Earth shield GND for the shield
Power Supply +10 +10V power supply Reference Voltage +10V – 5mA
OP +24V power supply for small equipments 24V 200mA max.
Communication RS+ / RS- port RS485 Use twisted-pair or shield cable
Analog input AI1 et AI2 Analog single-ended Analog voltage or current input – mode selected by jumpers AI1/AI2 (Reference ground : COM) ) – Voltage range -10V~+10V (Input resistor 45kOhm) Resolution 1/4000 – Current range 0mA~20mA Resolution 1/2000 (jumper select)
Analog output A01 et AO2 Providing analog voltage or current selected by jumper AO1/AO2 – The default setting is output voltage refer to to the function code A6.28/A6.29 (Reference ground : COM) - Voltage range 0V~10V – Current range 0/4mA~20mA
Multifonction input terminal X1~X5 Can be defined as multi-function digital input terminal – Refer to description of function code A6.00~A6.04 (A6 group) – Optocoupler isolation input – input resistor 3.3kOhm – Input voltage range of X1~X5 : 2~30V
Multifonction output terminal Y1 Bi-direction open collector output Can be defined as multi-function digital ouput terminal – Refer to description of function code A6.00~A6.04/A6.14 (A6 group) – Optocoupler isolation output – Max. working voltage : 30Vmax. Current 50mA
Common port COM Common port of 24V power supply Cooperate with other terminals

Variateur de fréquence Série CV100

No customer reviews for the moment.

Write your review

Frequency Inverter CV100 Series

Frequency Inverter CV100 Series

Frequency Inverter CV100 Series

200W - 400W - 750W - 1500W - 2200W

Write your review

3 other products in the same category :