Kinco KC100 Frequency inverter - Modbus
Frequency inverter
4T : triphase 380V~440V – 50Hz/60Hz // 2S : singlephase 200V~240V
Switching frequency: 0 to 12 kHz
Output frequency: 0 - 600Hz
Frequency control: Digital, analog voltage/current
1 RS485 Modbus port
1 reference voltage output 10V - 10mA
1analog inputs -10~+10V or 0mA~20mA
4 optocoupled multifunction digital inputs
1 analog outputs 0~10V or 0/4~20mA
1 optocoupled open collector output 30V - 50mA
1 relay output, 250VAC - 2A, 30VDC - 1A
1 power supply output +24V - 200 mA
■ Specification, model and technical parameters of KC100 series inverter
Inverter model | Power capacity (kVA) | Input current (A) | Output current (A) | Adaptative motor (kW) |
200V~240V50Hz/60Hz single phase | ||||
KC100-2S-0R40G | 1.0 | 5.3 | 2.5 | 0.4 |
KC100-2S-0R75G | 1.5 | 8.2 | 4.0 | 0.75 |
KC100-2S-01R5G | 3.0 | 14.0 | 7.5 | 1.5 |
KC100-2S-02R2G | 4.0 | 23.0 | 10.0 | 2.2 |
380V~480V 50Hz/60Hz three phase | ||||
KC100-4T-0R75G | 1.5 | 3.4 | 2.3 | 0.75 |
KC100-4T-01R5G | 3.0 | 5.0 | 3.7 | 1.5 |
KC100-4T-02R2G | 4.0 | 5.8 | 5.5 | 2.2 |
KC100-4T-03R7G | 5.9 | 10.5 | 8.8 | 3.7 |
KC100-4T-05R5G | 8.5 | 14.5 | 13.0 | 5.5 |
■ Specification, model and technical parameters of KC100 series inverter
• Overcurrent suppression protection: real-time current monitoring, automatically limit the current to no more than the overcurrent suppression point.
• Overvoltage suppression protection: When no brake resistor is connected, the operating frequency is automatically adjusted or the bus voltage rise is suppressed by flux braking.
• Undervoltage suppression protection (instantaneous non-stop): It can realize the function of instantaneous power loss without stopping.
• Wave-by-wave current limiting: When the sudden load or abnormal conditions such as momentary spikes in the current occurs, it will trigger the wave-by-wave current limit protection, which can limit the rise of the current to a certain extent, so that the current does not exceed the protection value of the inverter, and avoid reporting overcurrent fault and shutdown.
• Heat dissipation treatment: Independent air duct design, close to the IGBT power device efficient cooling, while the software built-in automatic reduction of carrier frequency according to temperature rise.
• Overvoltage, overcurrent fault protection.
• Input phase loss: Detect input phase loss based on bus voltage fluctuations. When phase loss occurs, a certain load is required to detect it.
• Output phase loss: Output phase loss fault can be quickly detected before and during operation.
• Phase to phase short circuit and short circuit to ground fault: quickly detected within 20ms before operation.
• Inverter module overtemperature, parameter self-learning failure, current detection failure, SVC stall failure, etc...
Dimensions:
Wiring :
Specifications
Voltage | 230 VAC or 380 VAC |
Drive power | 400 W or 750 W or 1500 W or 2200 W or 3700 W or 5500 W |
Brand | Kinco |
Inputs | 4 |
Analog inputs | 1 |
Analog outputs | 1 |
Interface | Modbus RS485 |