2CM880 Digital stepper driver - 80V 8A Kinco

2CM880 Microstep Driver - 70V 8A
- 8 levels of current adjustment from 2.4~8A
- 15 levels of resolution from 200~25,600 steps
- Inputs (Pulses/Dir or CW/CCW) 5~24V optocoupled with integrated limiting resistor, TTL compatible
- Pulse input frequency up to 400KHz
- Motor parameters self-identification system
- Automatic current reduction in case of inactivity
- Overvoltage and overcurrent protection

119.00 € Without Taxes 119.0 EUR 119.00 €

119.00 €

142.80 € 142.80 € with taxes

  • Brand
  • Max. Voltage
  • Max. current
  • Resolution setting

This combination does not exist.

Product Documents

Datasheet 2CM880
You have to login to access this document.
Manuel 2CM880
You have to login to access this document.

Internal Reference: 2CM880

Driver Micropas 2CM880

 

  • Digital Microstep Driver 2CM880
  • 15 subdivision levels 200~25 600 steps
  • Inputs (Pulses/Dir or CW/CCW) 5~24V opto isolated, TTL signal compatible
  • Input frequency up to 400kHz
  • Support parameter self-adaptive function
  • Automatic half-current function
  • Test running function
  • Over voltage and over current protection function
  • Micro-step filter function can smooth input pulse to reduce trasient motion of motor, make sure motor run more smoothly
  • Nema 23 end Nema 34 motors compatible

ItemDescription
Input Voltage 24~70VDC
Overvoltage protection 85VDC
UnderVoltage protection 15VDC
OverHeat protection 80°C (Température of Thermistor)
Phase current (peak) 2.4/3.2/4/4.8/5.69/6.4/7.2/8 A  –  8 settable values
Subdivision 200~25600 Pulses / tour -  15 subdivision levels in total
Adaptable Motors Nema 23 and Nema 34
Input Signals PLS (CW) - DIR (CCW) – FREE – Input voltage : 5~24VDC – Input current : 8mA@5VDC / 12mA@24VDC
Control Mode Pulse control : PLS + DIR – CW/CCW
Output signal ERR - open collector output – maximum current : 100mA
Operation Indicator Combination of RUN and ERR Led indicates different status
Protection Circuit Over voltage – Under voltage – Over current – Over heat
Cooling method Natural air cooling
Operation environnement Indoor - installed in the environnement free from direct sunlight – dust – corrosive gas – combustible gas – oil mist – steam and drip
Operation humidity <85%RH – non-condensing or water drops
Operation temperature 0°C~40°C
Storage temperature -20°C~70°C
Protection IP20
Subdivision setting (Unit : Pulses/Rev.) Current setting (Unit:A)
SW1 SW2 SW3 SW4=ON SW4=OFF SW6 SW7 SW8 RMS Peak
ON ON ON 200 1000 ON ON ON 5.7 8
OFF ON ON 400 2000 OFF ON ON 5.1 7.2
ON OFF ON 800 4000 ON OFF ON 4.5 6.4
OFF OFF ON 1600 5000 OFF OFF ON 4 5.6
ON ON OFF 3200 8000 ON ON OFF 3.4 4.8
OFF ON OFF 6400 10000 OFF ON OFF 2.8 4
ON OFF OFF 12800 20000 ON OFF OFF 2.3 3.2
OFF OFF OFF 25600 NA OFF OFF OFF 1.7 2.4

Function

DIP setting

Description
PLS + DIR SW6 & SW7 = ON – Others OFF Set DIP switches according to functions required when power OFF. Power On driver : RUN Led blinking is GREEN & ERR Led is RED. It means settings takes effect. Then Power OFF driver – reset subdivision and current for normal use
CW/CCW SW7 & SW8 = ON – Others OFF
Micro-Step smooth & dynamic filter disable SW5 & SW6 = ON – Others OFF
Micro-Step smooth filter enable SW5 & SW7 = ON – Others OFF
Micro-Step dynamic filter enable SW5 & SW8 = ON – Others OFF
Test motor parameter upon power on disable SW6 & SW7 & SW8 = ON – Others OFF
Test motor parameter upon power on enable SW5 & SW6 & SW7 = ON – Others OFF
Test running function SW6 & SW8 = ON – Others OFF Motor running @80RPM
Automatic half-current SW5 = ON – Others OFF Set SW5=ON to enable automatic half-current. Phase current will reduce to half of the set value after motor stops for 1.5s




Accessories

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.

Specifications

Brand Kinco
Max. Voltage 80 V
Max. current 8 A
Resolution setting DIP-switches
Your Dynamic Snippet will be displayed here... This message is displayed because you did not provided both a filter and a template to use.